Página 1

HEALTH CARE COMMUNICATION SYSTEMfor Nursing Homes & Health Care FacilitiesNHX SYSTEM83873900 0602E– 1 –INSTALLATION MANUALc

Página 2

– 10 – NHX-80X1. Power on LED, green2. Front cover screw (2)3. Power switch3-gang mounting123340 98460(18- ")/18(13- ")/38(3- ")

Página 3

– 11 – NHR-3TS  NHR-4A2-gang mountingSingle-gang mountingSingle-gang mounting1. Lamp cover (2)Red lamps inside1. Lamp cover White & red lamps in

Página 4

– 12 – System Features1. Listed UL1069 Patient to Staff Communication System for up to 80 stations.2. Voice-actuated handset or press-to-talk communi

Página 5 - NHR-3A-4

– 13 – Mounting locationNHX equipment is designed for indoor use only. NHX-80X must be wall-mounted on a UL Listed 3-gangbox or in a Listed electric

Página 6

Sub's Block& NumberBlock # Subs #BathroomPullcordYes or NoCorridor lampYes or NoUrgentCall Sw.Yes or NoZone #Assigned– 14 –3. INSTALLATION &a

Página 7

– 15 – Initializing NHX-80X for Sub stationsThe NHX-80X CCU must be set to zero after all the sub station numbers are programmed.Proceed as follows;1

Página 8 - 22 NAMES & FEATURES

– 16 –• NHX-80X1. Subs trunk lines11 ~ 16: for Block 121 ~ 26: for Block 231 ~ 36: for Block 341 ~ 46: for Block 451 ~ 56: for Block 561 ~ 66: for Blo

Página 9

– 17 –1 ~ 6: Connect 3P cable to Subs Trunk line. Ten stationsper trunk, connected to NHX-80X 11 - 16 (up to81 - 86) terminals.ZL: Zone light to a Zon

Página 10

To: NHX-50M To: NHR-SP Cable 5P 6 parallel conductorsDistance 65' w/22AWG 65' w/22AWG(20m w/0.65mmø) (20m w/0.65mmø)– 18 –*When

Página 11 - 5-gang mounting

To: Zone lightCable 5 parallel conductorsDistance 165' w/18AWG(50m w/1.0mmø)– 19 –Schematic diagram of Zone light NHR-3A-4WIRING DIAGRAMS2. Zon

Página 12

– 2 –CONTENTSPrecautions on Installation & Wiring ... 31 System Outline & Components ...

Página 13 - 33 INSTALLATION & WIRING

– 20 –Trunk line from NHX-80X to sub stations should beAiphone specified cable or UL Listed cable (3 twisted pair).• If 4-zone lamp is included, use 4

Página 14

– 21 –5. Bathroom call sub station: NHR-3TSWIRING DIAGRAMS4. Bedside sub stations w/Corridor lamp & Bathroom PullcordTake G terminal to earth gr

Página 15

– 22 –WIRING DIAGRAMSMulti-Station Patient Room Applications1. Four bed application covered by four NH-1SA/A sub stationswith a common bathroom pullco

Página 16

– 23 –WIRING DIAGRAMSMulti-Station Patient Room Applications2. Max. 12 bed application covered by six NH-2SA/A sub stationswith or without a common ba

Página 17

– 24 –44 MOUNTINGThe NHX-80X should be mounted on either 3-gang box or on inside UL Listed electrical enclosure.To open the front cover;1. On the NHX-

Página 18

– 25 –4. MOUNTING Mounting NHX-50M master stationAs shown, NHX-50M can be wired to NHX-80X CCU, using terminal cord supplied.At NHX-50M end, plug in

Página 19 - 2. Zone l

– 26 –NHR-3TS Sub station4. MOUNTING 2-gang semi-flush mounting (NH-1SA, NH-2SA, NHR-SP, NHR-3TS)The sub station flush-mounts in 2-gang box (UL Lis

Página 20

– 27 –4. MOUNTING NHR-4A1. Remove the lamp cover, pressing on both sides.2. Terminate 3 wires from NH-1SA/A or NH-2SA/Abedside sub.3. Mount NHR-4A o

Página 21 - WIRING DIAGRAMS

– 28 –• Receiving a Routine Call (Bedside)At NHX-50M55 OPERATIONS on NHX-50MSpeakerHandsetPower on LEDMicDirectorySub call-in LEDSub Selector buttonOF

Página 22

– 29 –5. OPERATIONS on NHX-50M• Volume AdjustmentsSpeaker receive voice volume & call tone signal areadjustable as needed on the left side of NHX-

Página 23

– 3 –PRECAUTIONS ON INSTALLATION & WIRINGPRECAUTIONS ON INSTALLATION & WIRINGWARNING1. Do not connect a power supply other than Aiphone Model

Página 24 - 44 MOUNTING

– 30 –Type of calling Call tone LightAt NHX-50M Master station• Receiving Routine callSingle chime, every 6 sec. Blinking, every 2 sec.Bathroom call (

Página 25

– 31 –6. TECHNICAL PRECAUTIONSRESET switchDo not use RESET switch except for initializing ortesting the NHX-80X. If RESET is pressed while a callis b

Página 26

– 32 –Other Operations(1) On a corridor lamp, the white lamp steadily lit (duringroutine call) may vary if another bathroom call orcord-out trouble ca

Página 27 -  NHR-7A

– 4 –1The NHX is a Health Care Communication System, exclusively designed for patient to staffcommunications in health care facilities. The NHX syste

Página 28 - 55 OPERATIONS on NHX-50M

– 5 –Sub Trunk line 1PS24PS24PS24 PS24PS24Sub stationNHR-3TS6(3P)To the farthest sub, max.165' (50m) withmin. 22AWG wire.Sub trunk line must note

Página 29 - NHX-50M side view

– 6 – COMPONENTS AVAILABLE• Central Control Unit • Urgent bathroom call sub station(common area)• Bedside sub stations• Master station & Add-on s

Página 30

– 7 – Accessories: Aiphone Models & UL Listed locally available• Zone light 4-zone indicator light. Max. 4 units.(NHR-3A-4) Up to 2 units powere

Página 31 - 6. TECHNICAL PRECAUTIONS

– 8 –22 NAMES & FEATURES NHX-50MDesk use onlyNHX-50M11. Handset 12. Speaker 13. Directory 14. Sub call-in LED 15. Sub selector button16. Power o

Página 32

– 9 – NHX-30GNHX-30G1. Directory2. Sub call-in LED3. Sub selector button NH-1SA/A2-gang mounting1. Speaker/mic.2. CANCEL button (for routine call on