Aiphone AI-900 Especificações

Consulte online ou descarregue Especificações para Sistemas de segurança - controlo de acesso Aiphone AI-900. Aiphone AI-900 Specifications [en] Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 2 - TABLE OF CONTENTS

107.2. Equipment Functions• AI-900MF Main FrameThe AI-900MF accommodates the following cards: Up to 2 AI-900MS or AI-900AL Cards (both cards may bemix

Página 3 - 14. SPEECH AND FUNCTION TESTS

118. AI-900MF MAIN FRAME NOMENCLATURE AND FUNCTIONS123456 7 891011121. AC Input ConnectorsConnect to the AC output terminal of theAI-PU200 power trans

Página 4

129. INSTALLATION AND CONNECTION PROCEDURES(1) System DesignExchange/Station Configuration, Wiring Schedule and Station Numbering Schedule(2) Equipme

Página 5

1310. EQUIPMENT INSTALLATION10.1. AI-900MF Main Frame10.1.1. Rack mountingStep 1. Attach the supplied rack mounting brackets to the frame.Mounting bra

Página 6 - 2. FCC REQUIREMENTS

1410.1.2. Wall mounting (Optional AI-YC303 Wall Mounting Frame is required.)Step 1. Mount the AI-YC303 bracket to the wall.Wood screw 5.1x38Knockout (

Página 7

1510.2. AI-PU200 Power Transformer Unit10.2.1. Rack mountingStep 1. Remove the 4 mounting screws, and attach the supplied wall mounting brackets to th

Página 8 - 6. INSTALLATION PRECAUTIONS

1610.2.2. Wall mountingStep 1. Remove the 4 mounting screws, and attach the supplied wall mounting brackets to the transformerusing the removed screws

Página 9 - 7.1. System Configuration

1710.3. AI-RS150, AI-RS160, AI-RS170 and AI-RS180 Substations Mount the substation to an electrical box mounted in the wall.AI-RS150/-RS160/-RS170/-RS

Página 11

19CR2032BATT1AI-900MF11. AI-900MF CARD INSTALLATION 11.1. Backup Battery InstallationCautionAll cards contain many CMOS ICs which are easily damaged b

Página 12

2TABLE OF CONTENTS1. SAFETY PRECAUTIONS ... 42. FCC REQUIREMENTS ...

Página 13 - 10. EQUIPMENT INSTALLATION

2011.2. Card InstallationStep 1. Remove each card from its static-protective bag, and install it in its designated position in the MainFrame. • For th

Página 14

2112. WIRING12.1. Wiring from the Station or Outside LineStep 1. Remove the main frame's bottom panel as shown below.Step 2. Connect stations or

Página 15

2212.2. Supplied Connector ConnectionUse the supplied connectors for exchange connections as follows. Step 1. Insert a cable into the connector and ti

Página 17 - Dimensional diagram

24[Connection]Use 2 twisted pair cables with a modular jack fitted at each one end to connect the AI-MS900 to theAI-900MS. Refer to the following tabl

Página 18

2512.3.2. External recording device and AI-900MS connectionAn external recording device can be connected to each master station line. [Connection]To c

Página 19 - ATTENTION

2612.4. AI-MS900 Master Station Connection and Adjustment12.4.1. External speaker connectionFollow the procedures below when connecting an external sp

Página 20 - 11.2. Card Installation

2712.5. AI-900AL Telephone Interface Card Connection12.5.1. Telephone and AI-900AL connectionThe AI-900AL can be interfaced with up to 2 commercial te

Página 21 - 12. WIRING

28[Setting telephone's talking volume levels]When the talking volume is low, set it using the switch SW101 (for Line 1) or SW201 (for Line 2) on

Página 22

2912.5.2. External recording device and AI-900AL connectionAn external recording device can be connected to each telephone line. [Connection]To connec

Página 23

312. WIRING12.1. Wiring from the Station or Outside Line ... 2112.2. Supplied Connector Co

Página 24

3012.6. AI-900RS Substation Interface Card Connection12.6.1. Substation and AI-900RS connection The AI-900RS can be interfaced with up to 16 substatio

Página 25

3112.6.2. External amplifier and AI-900RS connection 1-core shielded cable1 twisted pair cableAI-900RSCN1CN5Voice outputVoice inputHOTHOTGNDGND(For pa

Página 26

3212.7. AI-900CO Outside Line Interface Card Connection12.7.1. Outside line and AI-900CO connectionThe AI-900CO can be interfaced with up to 2 outside

Página 27

3312.7.2. External recording device and AI-900CO connectionAn external recording device can be connected to each telephone line. [Connection]To connec

Página 29

3512.8.2. External sound source and AI-900AF connectionThe External Sound Source Distribution function can be operated using the AI-900AF. [Connectio

Página 30

3612.9. AI-900TI Tie-Line Interface Card Exchange InterconnectionUp to 16 exchanges can be tie-line interconnected using the AI-900TI card. [Connectio

Página 31 - INPUT OUTPUT

37Connect as shown below.Exchange interconnection by means of AI-900TI 2 twisted pair cables 2 twisted pair cables 2 twisted pair cables 2 twisted pai

Página 32

38[Exchange Number Setting]When interconnecting the exchanges using the AI-900TI, assign the exchange number to each exchange withthe SW1 switch locat

Página 33

3912.10. AI-900MF Main Frame and AI-PU200 Power Transformer Connection[Connection]Connect as shown below using 2 parallel pair cables. Use cables with

Página 35

4013. MAIN FRAME AND PC CONNECTION13.1. Programming PC Connection13.1.1. Direct connection by means of RS-232CUsing the RS-232C cable, connect the pro

Página 36

4113.1.2. Connection via modemConnect as shown below.Connection via modem (Programming PC) AI-900MF ModemModemCOM2COM11 DCD2 RXD3 TXD4 DTR5 GND6 DSR7

Página 37 - Connect as shown below

4213.2. Operation Log PC Connection13.2.1. Direct connection by means of RS-232CUsing the RS-232C cable, connect the operating log PC to the AI-900MF

Página 38 - Exchange No. setting

4313.2.2. Connection via modemConnect as shown below.Connection via modem (Operation log PC) AI-900MF ModemModemCOM2COM11 DCD2 RXD3 TXD4 DTR5 GND6 DSR

Página 39 - [Connection]

4414. SPEECH AND FUNCTION TESTSUsing installed equipment, perform both speech and function tests after system programming completion. 14.1. Speech Tes

Página 40

45Note: The design and specifications are subject to change without notice for improvement. • AccessoriesPower Source 20 V AC, 24 V DCCurrent Consump

Página 41 - 13.1.2. Connection via modem

46Note: The design and specifications are subject to change without notice for improvement. • Accessories2-pin dedicated connector ...

Página 42

47Note: The design and specifications are subject to change without notice for improvement. • Accessories4-pin dedicated connector ...

Página 45 - 15. SPECIFICATIONS

62. FCC REQUIREMENTS (1) The AI-900 complies with FCC Rules, Part 68. On this equipment is a label which contains, among otherinformation, the FCC Par

Página 46

73. INDUSTRY CANADA REQUIREMENTS (1) ''NOTICE: This equipment meets the applicable Industry Canada Terminal Equipment TechnicalSpecification

Página 47

84. GENERAL DESCRIPTIONThe AI-900 Security System is a voice communication system that permits calls to be quickly and easilymade - even in emergency

Página 48

97. SYSTEM CONFIGURATION AND EQUIPMENT FUNCTIONS7.1. System ConfigurationAI-900 Exchange (1)AI-900 Exchange (2)AI-900 Exchange (16)Rack Mount PanelAI-

Comentários a estes Manuais