Aiphone AX-248C Especificações Página 8

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 7
AX Quikstart Guide
Pg. 8
AX-084C
16-7/8”
(
13-3/16” Depth
)
3-7/16”
Brown V+ to Coax Core
Red V- to Coax Braid
Yellow
Green
Orange
Blue
Monitor / DVR
5’ max
Blue
White
Orange
Orange
To Bell/Light
& Power
RY-ES
Red
Black
PS-2420UL
-
+
N/O Dry Input
(foot switch)
1) Connect Brown (V+) and Red (V-) to coax input of standard monitor / DVR.
Maximum wire run is 5’. Output is 1Vp-p, 75 ohm.
2) Connect Orange and Yellow wires to either an IER-2 chime extension
speaker, or to the White and Blue wires on the RY-ES relay for an external
device signaling.
3) Connect the Green and Blue wires to any normally open dry contact
device, to be used in place of the talk button on the master. Contact
device should be no more than 50’ from the master.
AX Master options via included 6-pin connector
RY-24L color code:
Red = Positive Trigger
Black = Negative
Brown = Common
Orange = N.O. Contact (door strike)
Yellow = N.C. Contact (mag lock)
AX-DV
7-11/16"
3-15/16" 1"
AX-DV
7-11/16"
3-15/16" 1"
To + 24VDC
To - 24VDC
blk
blk
red
red
Lock
Power
brn
org
Strike
brn
yel
Mag Lock
Lock
Power
Use Brown and Orange wires
when connecting to electric
strike.
Use Brown and Yellow wires
when connecting to maglock.
Connecting to Strike/Maglock with RY-24L